AV Control Unit
POWER SUPPLY AND GROUND CIRCUIT
AV CONTROL UNIT : Diagnosis Procedure
1.CHECK FUSES
Check that the following AV control unit fuses are not blown.
Are the fuses OK?
YES - GO TO 2.
NO - If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.
2.POWER SUPPLY CIRCUIT CHECK
1. Disconnect AV control unit connectors M42 and M45.
2. Check voltage between the AV control unit connectors M42 and
M45 and ground.
Are the voltage results as specified?
YES - GO TO 3.
NO - � Check connector housings for disconnected or loose terminals.
- Repair harness or connector.
3.GROUND CIRCUIT CHECK
1. Ignition OFF.
2. Check continuity between AV control unit harness connectors
M42 and M45 and ground.
Are the continuity results as specified?
YES - Inspection End.
NO - Repair AV control unit ground.