Diagnosis Procedure
POWER WINDOW MOTOR
PASSENGER SIDE : Diagnosis Procedure
Front Power Window Motor RH Circuit Check
1. CHECK FRONT POWER WINDOW SWITCH RH OUTPUT SIGNAL
1. Disconnect front power window motor RH.
2. Turn ignition switch ON.
3. Check voltage between front power window motor RH connector and ground.
Is the measurement value within the specification?
YES - GO TO 2
NO - Replace power window and door lock/unlock switch RH. Refer to Service and Repair.
2. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect power window and door lock/unlock switch RH.
3. Check continuity between power window and door lock/unlock switch RH connector and front power window motor RH connector.
4. Check continuity between power window and door lock/unlock switch RH connector and ground.
Is the inspection result normal?
YES - GO TO 3
NO - Repair or replace harness.
3. CHECK FRONT POWER WINDOW MOTOR RH
Check front power window motor RH. Refer to Component Inspection.
Is the inspection result normal?
YES - Check intermittent incident. Refer to Intermittent Incident.
NO - Replace front power window motor RH. Refer to Service and Repair.