Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

CAN




M&A BRANCH LINE CIRCUIT

Diagnosis Procedure


1. CHECK CONNECTOR

1.Turn the ignition switch OFF.
2.Disconnect the battery cable from the negative terminal.
3.Check the terminals and connectors of the unified meter and A/C amp. for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES- GO TO 2.
NO- Repair the terminal and connector.

2. CHECK HARNESS FOR OPEN CIRCUIT

1.Disconnect the connector of unified meter and A/C amp.
2.Check the resistance between the unified meter and A/C amp. harness connector terminals.





Is the measurement value within the specification?
YES- GO TO 3.
NO- Repair the unified meter and A/C amp. branch line.

3. CHECK POWER SUPPLY AND GROUND CIRCUIT

Check the power supply and the ground circuit of the unified meter and A/C amp. Unified Meter and A/C Amp.
Is the inspection result normal?
YES (Present error)-Replace the unified meter and A/C amp. Exploded View.
YES (Past error)-Error was detected in the unified meter and A/C amp. branch line.
NO- Repair the power supply and the ground circuit.