C14: Check For Short to B+
Ignition switch to position 0
Disconnect EM010
Inside ECM housing
Disconnect EM012
Inside ECM housing
Measure the voltage between EM010/023 and EM012/017.
Ignition switch to position II
- Is the voltage 0 (zero) V?
Yes
GO to C15 C15: Check For Short to B+
No
Inspect harness/connectors EM010, EM012, and EM022 for corrosion, damaged/pushed back pins. Repair as required and reconnect plug(s).
GO to C18 C18: End