Full Open Retractable Roof Initialization Procedure
FULL OPEN RETRACTABLE ROOF INITIALIZATION PROCEDURE
Limits
Temperature
The temperature must be between 5°C (41°F) to 45°C (113°F) for initialization to be performed, Outside of this temperature range an initialization will not start and if requested by a diagnostics scan tool, the Electronic Control Unit will send the proper reject code.
Voltage
Vehicle voltage must be maintained between 11V - 15V.
Roof Initialization Procedure
1. Ensure the Vehicle is in the RUN power mode with the engine running.
2. If roof is in a position other than fully closed; press roof switch center button for less than 1 second and wait for the roof to close.
3. With roof fully closed: Push and hold the roof switch center button for more than 20 seconds and do not release until the following roof cycle is complete:
- Front of Roof will Close (Then Stall)
- Rear of Roof will Close (Then Stall)
- Rear of Roof will Open
- Rear of Roof will Close
- Rear of Roof Vents (approx two inches)
- Front of Roof will Open
- Front of Roof will Close
- Rear of Roof Closes from Vent
4. Once all movement has stopped, release the roof switch center button. Roof system initialization is now complete.