Initialization
FULL OPEN RETRACTABLE ROOF INITIALIZATION PROCEDURE
NOTE: There are two initialization procedures that may be used when servicing the full open retractable roof. The Diagnostic Scan Tool procedure requires the use of the diagnostic scan tool and a dedicated routine that is used to initialize the full open retractable roof following replacement or reprogramming of the SUNRoof (SUNR) electronic control unit. The Manual procedure is used following service of any of the retractable roof hardware components.
Limits
Temperature
The temperature must be between 5°C (41°F) to 45°C (113°F) for initialization to be performed, Outside of this temperature range an initialization will not start and if requested by a diagnostics scan tool, the Electronic Control Unit (ECU), (sometimes referred to as the Power Top Control Module) will send the proper reject code.
Voltage
Vehicle voltage must be maintained between 11V - 15V.
Diagnostic Scan Tool Procedure
1. Select "SUNR" on the diagnostic scan tool.
2. Select "MORE OPTIONS".
3. Select "SYSTEM TESTS".
4. Select "SUNROOF INITIALIZATION".
5. Follow the on-screen prompts.
Manual Procedure
1. Ensure the Vehicle is in the RUN power mode with the engine running.
2. If roof is in a position other than fully closed; press roof switch center button for less than 1 second and wait for the roof to close.
3. With roof fully closed: Push and hold the roof switch center button for more than 20 seconds and do not release until the following roof cycle is complete:
- Front of Roof will Close (Then Stall)
- Rear of Roof will Close (Then Stall)
- Rear of Roof will Open
- Rear of Roof will Close
- Rear of Roof Vents (approx two inches)
- Front of Roof will Open
- Front of Roof will Close
- Rear of Roof Closes from Vent
4. Once all movement has stopped, release the roof switch center button. Roof system initialization is now complete.