Test T

PINPOINT TEST T: DTC B1676 BATTERY PACK VOLTAGE OUT OF RANGE


Test T1:






Normal Operation
The DSM is powered by battery voltage from circuit 29-AH35 (OG/YE) and 30-AH80 (RD) and is supplied ground on circuit 31-AH80 (BK).

Possible Causes
DTC B1676 battery pack voltage out of range can be caused by:
- a faulty DSM.