Operation CHARM: Car repair manuals for everyone.

Test C: DTC C1095 - ABS Hydraulic Pump Motor Circuit Failure

Pinpoint Test C: DTC C1095 - ABS Hydraulic Pump Motor Circuit Failure
Refer to Vehicle/Diagrams, Vehicle Dynamic Systems for schematic and connector information.

Normal Operation
The operating voltage required to operate the hydraulic pump motor is between 10 and 17 volts.

Fused battery voltage for the hydraulic pump motor is supplied to the ABS module from battery junction box (BJB) fuse 6 (40A) along circuit SBB06 (BN/RD), ground is provided along GD120 (BK/GN).

This pinpoint test is intended to diagnose the following:
^ Fuse(s)
^ Wiring, terminals or connectors
^ Hydraulic pump motor
^ ABS module

C1:




C2-C4:




C5: