Operation CHARM: Car repair manuals for everyone.

Test C: DTC B1255 Or DTC B1257 - Air Temperature External Sensor Circuit Open Or Short To Ground

PINPOINT TEST C: DTC B1255 OR DTC B1257 - AIR TEMPERATURE EXTERNAL SENSOR CIRCUIT OPEN OR SHORT TO GROUND

Normal Operation
Under normal operation, the ambient air temperature sensor receives a ground from the HVAC module - electronic automatic temperature control (EATC) through circuit RH104 (BU/BN)/RMC32 (GN/BU). A 5-volt reference voltage is supplied to the ambient air temperature sensor from the HVAC module - EATC through circuit VH407 (YE/GN).

- DTC B1255 Air Temperature External Sensor Circuit Open - The module senses no voltage drop on the sensor reference voltage circuit, indicating an open circuit.
- DTC B1257 Air Temperature External Sensor Circuit Short to Ground - The module senses excessive voltage drop on the sensor reference voltage circuit, indicating a short directly to ground.

This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Ambient air temperature sensor
- HVAC module - EATC


C1-C2:






C2-C3:






C4-C6:






C6-C7: