Operation CHARM: Car repair manuals for everyone.

Inspection Procedure 14

INSPECTION PROCEDURE 14: KOS Timer Lock Function does not Work.

CAUTION: Before replacing the ECU, ensure that the power supply circuit, the ground circuit and the communication circuit are normal.

OPERATION
After the door is unlocked with the keyless entry function, if no operation is performed, the door is locked when the time specified by a customization function has elapsed. However, an open signal from any door, key reminder switch OFF (with the key inserted) signal, or ignition push switch ON signal has been input to ETACS, the KOS timer will not operate.

PROBABLE CAUSES
- Malfunction of ETACS-ECU.
- Malfunction of the door switches.

DIAGNOSTIC PROCEDURE

Required Special Tools:
MB991223: Harness Set
MB992006: Extra Fine Probe
MB991958: Scan Tool (M.U.T.-III Sub Assembly)
MB991824: V.C.I.
MB991827: M.U.T.-III USB Cable
MB991910: M.U.T.-III Main Harness A

STEP 1. Using scan tool MB991958, read the diagnostic trouble code.






CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.

1. Connect scan tool MB991958. Refer to "How to connect scan tool (M.U.T.-III)." How To Connect The Scan Tool (M.U.T.-III)
2. Turn the ignition switch to the "ON" position.
3. Check whether the KOS-ECU related DTC is set.
4. Turn the ignition switch to the "LOCK" (OFF) position.

Q: Is the DTC set?

YES : Diagnose the KOS-ECU.

NO : Go to Step 2.

STEP 2. Retest the system.
Check that the KOS timer lock function operates.

Q: Is the check result normal?

YES : Intermittent malfunction (Refer to General (Body and Chassis), How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction).

NO : Perform troubleshooting for each door switch.