P1490

DTC P1490 VACUUM CUT VALVE BYPASS VALVE

Description




COMPONENT DESCRIPTION
The vacuum cut valve bypass valve is a solenoid type valve and generally remains closed. It opens only for on board diagnosis.

The vacuum cut valve bypass valve responds to signals from the ECM. When the ECM sends an ON (ground) signal, the valve is opened.

Consult-II Reference Value In Data Monitor Mode:






On Board Diagnosis Logic
Malfunction is detected when an improper voltage signal is sent to ECM through vacuum cut valve bypass valve.

Possible Cause
- Harness or connectors
(The vacuum cut valve bypass valve circuit is open or shorted.)
- Vacuum cut valve bypass valve

DTC Confirmation Procedure

NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 10 seconds before conducting the next test.

TESTING CONDITION: Before performing the following procedure, confirm that battery voltage is more than 11V at idle speed.

WITH CONSULT-II
1. Turn ignition switch "ON".




2. Select "DATA MONITOR" mode with CONSULT-II.
3. Start engine and wait at least 5 seconds.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure" below.

WITH GST
Follow the procedure "WITH CONSULT-II" above.

EC-BYPS/V-01:




Wiring Diagram

Diagnostic Procedure Step 1 - 3:




Diagnostic Procedure Step 4 - 8:




Diagnostic Procedure

Component Inspection

VACUUM CUT VALVE BYPASS VALVE

With CONSULT-II
1. Reconnect harness disconnected connectors.
2. Turn ignition switch ON.




3. Perform "VC/V BYPASS/V" in "ACTIVE TEST" mode.




4. Check air passage continuity and operation delay time under the given conditions.
Operation takes less than 1 second.







With GST
Check air passage continuity and operation delay time under the given conditions.
Operation takes less than 1 second.