Operation CHARM: Car repair manuals for everyone.

P0043


P0043, P0044 HO2S3 HEATER





Description

SYSTEM DESCRIPTION





The ECM performs ON/OFF control of the heated oxygen sensor 3 heater corresponding to the engine speed, amount of intake air and engine coolant temperature.

OPERATION









DTC Logic

DTC DETECTION LOGIC






DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10.5V and 16V at idle.
- GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
1. Activate "INSPECTION MODE 1" ( Inspection Mode 1) to start engine, and warm up engine to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Turn ignition switch ON (READY).
6. Drive vehicle at a speed of 80 km/h (50 MPH) or more for at least 3 consecutive minutes.

CAUTION:
Always drive vehicle in safe manner according to traffic conditions and obey all traffic laws.

NOTE:
Keep the vehicle speed as steady as possible during the cruising.
7. Check 1st trip DTC.
Is 1st trip DTC detected?
YES - Go to SEE Diagnosis Procedure.
NO - INSPECTION END




Diagnosis Procedure
1.CHECK GROUND CONNECTION
1. Turn ignition switch OFF.
2. Check ground connection E9. Refer to Ground Inspection in Circuit Inspection.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair or replace ground connection.
2.CHECK HO2S3 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 3 harness connector.
2. Turn ignition switch ON.





3. Check the voltage between HO2S3 harness connector and ground.





Is the inspection result normal?
YES - GO TO 4.
NO - GO TO 3.
3.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F58, F201
- IPDM E/R harness connector F10
- 15A fuse (No. 37)
- Harness for open or short between heated oxygen sensor 3 and fuse
- Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK HO2S3 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between HO2S3 harness connector and ECM harness connector.





4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES - GO TO 6.
NO - GO TO 5.
5.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F58, F201
- Harness for open or short between heated oxygen sensor 3 and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
6.CHECK HEATED OXYGEN SENSOR 3
SEE Component Inspection.
Is the inspection result normal?
YES - GO TO 8.
NO - GO TO 7.
7.REPLACE HEATED OXYGEN SENSOR 3
Replace heated oxygen sensor 3. Exploded View.

CAUTION:
- Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new sensor, clean exhaust system threads using oxygen sensor thread cleaner
[commercial service tool: (J-43897-18 or J-43897-12)] and approved anti-seize lubricant (commercial service tool).
- INSPECTION END
8.CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- INSPECTION END




Component Inspection
1.CHECK HEATED OXYGEN SENSOR 3 HEATER
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 3 harness connector.





3. Check resistance between HO2S3 terminals as follows.





Is the inspection result normal?
YES - INSPECTION END
NO - GO TO 2.
2.REPLACE HEATED OXYGEN SENSOR 3
Replace heated oxygen sensor 3. Exploded View.

CAUTION:
- Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new sensor, clean exhaust system threads using oxygen sensor thread cleaner
[commercial service tool: (J-43897-18 or J-43897-12)] and approved anti-seize lubricant (commercial service tool).
- INSPECTION END