Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake
CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 1 (RIGHT SIDE) INTAKE
Removal Procedure
1. Remove the air cleaner assembly.
2. Disconnect the engine wiring harness electrical connector (2) from the bank 1 intake camshaft position (CMP) actuator solenoid valve (5).
3. Remove the CMP actuator solenoid valve bolt.
4. Remove the CMP actuator solenoid valve.
5. Inspect the CMP actuator solenoid valve seal and replace as necessary.
Installation Procedure
1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator solenoid valve.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
3. Install the CMP actuator solenoid valve bolt.
Tighten the bolt to 10 Nm (89 lb in).
4. Connect the engine wiring harness electrical connector (2) to the bank 1 intake CMP actuator solenoid valve (5).
5. Install the air cleaner assembly. Service and Repair