B1795
SUPPLEMENTAL RESTRAINT SYSTEMS: OCCUPANT CLASSIFICATION SYSTEM: B1795: Occupant Classification ECU Malfunction
B1795 - Occupant Classification ECU Malfunction
DESCRIPTION
DTC B1795 is stored when a malfunction is detected in the occupant classification ECU.
Troubleshoot DTC B1771 first when both DTCs B1771 and B1795 are present.
HINT
- When DTC B1650/32 is stored as a result of troubleshooting the airbag system, perform troubleshooting for DTC B1795 of the occupant classification system.
- Use the Techstream to check for DTCs of the occupant classification ECU, otherwise the DTCs cannot be read.
INSPECTION PROCEDURE
PROCEDURE
1. CHECK FOR DTC
(a) Turn the ignition switch to ON, and wait for at least 60 seconds.
(b) Clear the DTCs stored in memory Reading and Clearing Diagnostic Trouble Codes.
HINT
- First clear the DTCs stored in the occupant classification ECU, and then clear the DTCs stored in the center airbag sensor.
- Use the Techstream to clear the DTCs of the occupant classification ECU, otherwise the DTCs cannot be cleared.
(c) Turn the ignition switch off, and wait for at least 10 seconds.
(d) Turn the ignition switch to ON, and wait for at least 60 seconds.
(e) Using the Techstream, check for DTCs of the occupant classification ECU Reading and Clearing Diagnostic Trouble Codes.
OK:
DTC B1795 is not output.
HINT
DTCs other than DTC B1795 may be output at this time, but they are not related to this check.
NG -- REPLACE OCCUPANT CLASSIFICATION ECU
OK -- USE SIMULATION METHOD TO CHECK Diagnosis System
2. REPLACE OCCUPANT CLASSIFICATION ECU
(a) Turn the ignition switch off.
(b) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
(c) Replace the occupant classification ECU Removal.
HINT
Perform the inspection using parts from a normal vehicle when possible.
NEXT -- Continue to next step.
3. PERFORM ZERO POINT CALIBRATION
(a) Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
(b) Turn the ignition switch to ON, and wait for at least 60 seconds.
(c) Using the Techstream, perform the zero point calibration Programming and Relearning.
OK:
"Zero Point Calibration is complete." is displayed.
NEXT -- Continue to next step.
4. PERFORM SENSITIVITY CHECK
(a) Using the Techstream, perform the sensitivity check Programming and Relearning.
Standard range:
27 to 33 kg (59.5 to 72.8 lb)
NEXT -- END