Installation
3MZ-FE CHARGING: GENERATOR:
INSTALLATION
1. INSTALL GENERATOR ASSEMBLY
(a) Install the generator with the 2 bolts, but do not fully tighten the bolts.
(b) Adjust the V belt tension by tightening the bolt.
(c) Tighten the 2 bolts.
Bolt A - Torque: 58 Nm (592 kgf-cm, 43 ft-lbf)
Bolt B - Torque: 18 Nm (184 kgf-cm, 13 ft-lbf)
(d) Install the generator wire with the nut.
Torque: 9.8 Nm (100 kgf-cm, 87 in-lbf)
(e) Connect the generator connector.
(f) Install the wire harness clamp.
2. INSPECT DRIVE BELT
HINT: (Charging System)
3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
4. PERFORM INITIALIZATION
HINT: (Repair Instruction - Initialization)