Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Installation








2GR-FE STARTING: STARTER: INSTALLATION

INSTALLATION

1. INSTALL STARTER ASSEMBLY
(a) Install the starter assembly with the 2 bolts.
Torque: 37 Nm (380 kgf-cm, 26 ft-lbf)
(b) Connect the wire harness to terminal 30 and install the nut.
Torque: 9.8 Nm (100 kgf-cm, 87 in-lbf)
(c) Cover the nut with the cap.
(d) Connect terminal 50 to the starter assembly.
2. INSTALL AIR CLEANER INLET NO.1 Installation
3. INSTALL AIR CLEANER ASSEMBLY WITH HOSE Installation
4. CONNECT BATTERY NEGATIVE TERMINAL
5. PERFORM INITIALIZATION

HINT: Repair Instruction - Initialization

(a) Some systems need initialization when disconnecting the battery terminal.