Removal
METER / GAUGE / DISPLAY: COMBINATION METER: REMOVAL
1. REMOVE UPPER INSTRUMENT PANEL ASSEMBLY
(a) Remove the upper instrument panel assembly Removal.
2. REMOVE NO. 1 HEATER TO REGISTER DUCT Removal
3. REMOVE COMBINATION METER ASSEMBLY
(a) Disconnect the connector.
(b) Disengage the clamp.
(c) Remove the 3 screws.