P2716
U760E AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSAXLE SYSTEM: P2716: Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
P2716 - Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
DESCRIPTION
Refer to the system description for DTC P2714 P2714.
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
ALL:
Malfunction (A):
Malfunction (B):
Malfunction (C):
Malfunction (D):
Malfunction (E):
TYPICAL MALFUNCTION THRESHOLDS
Malfunction (A) and (B):
Malfunction (C):
Malfunction (D):
Malfunction (E):
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs Reading and Clearing Diagnostic Trouble Codes.
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT CIRCUIT)
(a) Disconnect the ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
OK -- REPLACE ECM Components
2. CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
(a) Disconnect the harness connector from the wiring harness connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
3. INSPECT TRANSMISSION WIRE (SLT)
(a) Remove the wiring harness connector from the transaxle.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- INSPECT SHIFT SOLENOID VALVE SLT
OK -- REPLACE WIRING HARNESS CONNECTOR Components
4. INSPECT SHIFT SOLENOID VALVE SLT
(a) Remove shift solenoid valve SLT.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
(c) Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
OK:
Valve moves and makes an operating sound.
Text in Illustration
NG -- REPLACE SHIFT SOLENOID VALVE SLT Components