Connecting The Breakout Box
Connecting the breakout box
Special tools:
951 1510 Replaced by 9512866 951 1510 Replaced by 9512866
951 1428 Breakout box 951 1428 Breakout box
Caution! Avoid touching control module connector pins and corresponding cable harness connectors. There is a risk of electrostatic discharge, which could damage the control module. Relieve any charge on yourself and the tools to be used by holding the metal part of the tool and touching part of the body just before starting work.
General information
Visually check the connectors to ensure that the male and female terminals are not damaged and that the cables are properly connected to the terminals. The breakout box is designed to facilitate taking readings from cables and components when the control module is disconnected. The use of a breakout box reduces the risk of accidental short-circuits and damage to the connector pins.
- Ignition off
- Disconnect the control module connector.
Connect adapter 951 1510 Replaced by 9512866 951 1510 Replaced by 9512866 to the control module connector. Connect one or two breakout boxes 951 1428 Breakout box 951 1428 Breakout box to the adapter depending on the reading to be taken.
Disconnect the breakout box in reverse order.
Other information:
- To access and replace the SRS control module and connector, see Service and Repair
- For the location of the components, see Location of components Locations.
- For other values, see Signal specification Signal Specification.