Injector Cooling Fan - Reduced Output
87audi02Number: Group:
87-02
25
July 27, 1987
Fuel System
Applies To: 5000S 1984-1985
Subject: Injector Cooling Fan
Cause:
Reduced output from cooling fan due to incorrect polarity at fan electrical connector.
Production Change:
Not affected. Applies to injector cooling fan installation kit, P/N 443 998 219, (see Audi 5000 Protraining Update, page 54).
Service Solution: