Side Airbag Harness Connector, Disconnecting
Side Airbag Harness Connector, Disconnecting
WARNING: Before starting work on seats, connect VAS 5094 airbag adapter.
NOTE: Technician must be grounded before disconnecting ignition and Ground (GND) wiring; to ensure proper grounding, touch door striker or body.
- Grab side airbag harness connector - 1 - from behind.
- Pull catch - 3 - with one finger in direction of arrow (toward hand).
- At same time, use same hand to pull side airbag connector - 1 - forward (in direction of arrow).
- Using screwdriver - 1 -, push tab - 2 - over catch - 3 - and disconnect harness connector - 4 -.