Compressor Drive Plate With Overload Protection, Checking Run-Out and Adjusting
Compressor Drive Plate with Overload Protection, Checking Run-Out and Adjusting
- Remove compressor. Refer to => [ Compressor, 4- or 6-Cylinder ] .
- Clean flange at drive plate - A -
- Secure a dial gauge - B - with a dial gauge holder - C - (such as dial gauge holder (VW 387)) to the compressor.
- Set probe of dial gauge - D - on flange of drive plate - A - with a pre-tension of approximately 1.0 mm.
- Turn compressor drive unit - E - several rotations.
Specification: Run-out deviation is less than 0.21 mm (run-out of dial indicator, difference between smallest and largest measured value 0.2 mm maximum)
- If run-out deviation is greater than 0.2 mm, loosen bolts on drive plate. Refer to => [ Compressor Drive Plate with Overload Protection ] Compressor Drive Plate With Overload Protection and re-adjust drive plate.