Exhaust Flap Vacuum Reservoir, Checking
Exhaust Flap Vacuum Reservoir, Checking
Special tools, testers and auxiliary items required
- Hand vacuum pump VAS 6213 or hand vacuum pump V.A.G 1390
Work procedure
- Disconnect hose on vacuum diaphragm for exhaust flap at rear muffler.
- Connect Hand Vacuum Pump V.A.G 1390 or VAS 6213 to vacuum diaphragm.
- Generate vacuum using hand vacuum pump.
- Linkage must move toward front.
- Vent hand vacuum pump.
- Linkage must move toward rear.
If linkage does not move:
- Check linkage for ease of movement and check vacuum diaphragm for leaks.