A/C Compressor Regulator Valve, Checking Activation Signal






A/C Compressor Regulator Valve, Checking Activation Signal

- Switch off ignition.

- Connect the Climatronic control module (J255) A/C control head to the vehicle wiring harness.

- Disconnect the connector from the A/C system compressor (to the A/C compressor regulator valve (N280)).





- Recreate the connection between connector - A - and connector - B - on the compressor (to the A/C compressor regulator valve (N280)) using an adapter cable from the connector test kit (V.A.G 1594C).

An adapter cable can also be used for this test. To do this, e.g. use one connector each - A - and - B - (part number 1J0 973 702 and 1J0 973 802 and relevant terminal contacts), two standard sockets for banana connectors - C - and two wires with 0.5 mm 2 diameter.





- Connect DSO measuring leads 1 & 2 (VAS 5051/8 ) to the adapter leads.

- Measuring cable (signal wire) to terminal - 2 -.

- Measuring cable (shielded, ground) to terminal - 1 -.

- In Vehicle Diagnosis, Testing and Information System (VAS 5051A), select operating mode Test Instruments: " DSO" (digital storage oscilloscope)

- Setting 5V/div = 0.5 ms/div (5 volts DC voltage and 0.5 milliseconds per unit)

- Start the engine.

- Set the temperature preselect for the driver's and front passenger's side to "Low" on the Climatronic control module (J255) A/C control head.

- Switch on and off the activation of the A/C compressor regulator valve (N280) via the Climatronic control module (J255) A/C control head by operating the " auto" and "econ" buttons.

Shown on screen of oscilloscope, depending on setting of A/C control head Climatronic Control Module (J255):

- No square wave signal (A/C compressor regulator valve (N280) is not activated) for operating mode "OFF" or " Econ".

- A square wave signal with an impulse width - A - between 75% and 100% (A/C compressor regulator valve (N280) is activated) for operating mode "Auto" and temperature setting "Low".





The Fig. shows a signal with a duty cycle of approximately 80%.

Impulse width - A - is dependent on the desired cooling output, vehicle voltage, etc. (over the width of region - A -, voltage is regulated via A/C compressor regulator valve ( N280) by the Climatronic control module (J255 ) A/C control head).

The signal distance - B - is always 2 milliseconds (corresponds to frequency of 500 Hertz).

The duty cycle is determined by the ratio of impulse width - A - and signal distance - B -.

- The impulse width of the square wave signal changes depending on the Climatronic control module (J255) A/C control head setting and the measured environmental conditions (duty cycle between 100% and greater than 30%, the A/C compressor regulator valve (N280) is activated so that the compressor output necessary to reach the specified temperatures is achieved).

For operating mode setting "Auto" and temperature setting " Low", the A/C compressor regulator valve (N280) is activated so that the maximum permissible current of approximately 0.6 A to 0.8 A flows via the A/C compressor regulator valve (N280) (maximum compressor output).

In control mode, actuation time is governed by required cooling output and vehicle electrical system voltage, for example. It is however always of sufficient duration to achieve a mean current of 0.3 A.