Fuel Level Sensor: Testing and Inspection
Fuel Level Sensor 2 G169, Checking
Special tools, testers and auxiliary items required
- Portable multimeter V.A.G 1526 C
- Connector test set V.A.G 1594 C
Test sequence
- Remove rear seat bench.
- Unbolt cover for left locking flange - arrows - .
- Disconnect electrical harness connector - arrow - at left locking flange.
- Connect hand multimeter V.A.G 1526 C between terminal - 2 - and - 3 - for resistance measurement.
NOTE:
- If measured value is 0 Ohm there is a short circuit. If measured value is infinity Ohm there is and open circuit in the wiring.
- To check resistance values "tank full" or "tank empty" , the Fuel Level Sensor 2 G169 must be removed and the sensor floater must be placed in upper or lower end position.
- With Fuel Level Sensor 2 G169 removed, the following values are obtained because of the greater deflection of the floater arm