Notes on the BMW Diagnostic System
General
The terminal R (ignition switch in position 1 or 2) must be switched on to start the diagnostic procedure. The ignition can be switched off again and the ignition key removed from the ignition switch after output of the ignition page.
Note: In a series of modules, the diagnostic procedure can only be started when the vehicle is unlocked and the terminal R is switched on. However, also in this case, the ignition can be switched off and the vehicle locked again after output of the identification page.
Test Procedure
The *D* test procedure (BMW MoDIC *D* status monitoring) makes it possible to check all components and contacts which have an influence on the control of the interior lights.
Activation of Interior Lights
It is possible to activate the interior lights as part of the guided test procedure. However, activation is only possible when:
- the vehicle is unlocked.
- the ignition switch is in position 1 or 2.
The doors should also be closed otherwise the lights would be switched on without the activation function.
In the BMW MoDIC, the lights are activated by way of *D* component activation.
Abbreviations
FH Power windows
LB Interior lights
SG Control unit
TSH Door lock heating
ZVM Central locking module
ZV Central locking system