Air Cleaner Housing: Service and Repair
- Switch off ignition.- Twist and pull off connector (1).
- Remove hose from idle speed actuator in rubber gaiter (2).
- Unfasten hose clip and remove bellows.
- Unfasten nuts (3 and 4).
- Remove suction filter housing with mass air flow sensor and rubber gaiter.
- If necessary, unfasten clips (3 and 4).
- Disconnect intake filter housing from mass air flow sensor.
Installation Note: Install housing support in rubber mount.
- First install intake snorkel.
- Interrogate fault memory of DME control unit, check faults in memory, rectify faults and clear fault memory.