Operation CHARM: Car repair manuals for everyone.

2D06 - P1424 (DME)

2D06 - P1424

Information saved in
DME

Fault code
2D06 - P1424

Fault text
Air-mass system

Fault description
Mass or Volume Air Flow Too High

Condition for fault identification
Test condition:
Mass airflow data monitor
6 % < relative charge <120 %
-20� < induction air temperature < 85 �C
560 1 rpm < engine speed < 7200 rpm
Time after start > 30 sec.
Regardless of whether EVAP is active/inactive
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system >= 10 V

Condition for fault memory entry
0.2 sec.

Action in service
1) Visual inspection of HFM plug contacts
2) Check wiring between HFM and DME
3) Check induction system/crankcase for leaks (crankcase
vacuum control can allow excess air from the crankcase to
flow into the intake manifold, for instance, if vacuum line
from brake booster to vacuum pump is leaking)

Fault effect and breakdown warning


Driver information
Warning light:
MIL ON

Service instruction
none