2FDB - P120C (DME)
2FDB - P120CInformation saved in
DME
Fault code
2FDB - P120C
Fault text
Crankcase ventilation, electric ATIC39
Fault description
Crankcase Ventilation Diagnostic Valve Open Circuit
Condition for fault identification
Test condition:
Terminal condition: Terminal 15 on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
90 sec.
Action in service
none
Fault effect and breakdown warning
Driver information
Warning light:
NO
Service instruction