Condition on Fault Memory Entry - 1
2A99 - P0017Information saved in
DME
Fault code
2A99 - P0017
Fault text
Crankshaft - exhaust camshaft, correlation
Fault description
Crankshaft Position - Camshaft Position Correlation (Bank 1
Sensor B)
Condition for fault identification
Test condition:
NW signal position detection monitor.
Terminal condition: Terminal 15, engine on
Condition for fault memory entry
On every camshaft flank when the flank was outside
tolerance. Following successful synchronization.
Action in service
1. Check positions (valve timing setting) of camshaft
reluctors
2. Check timing chain and chain tensioner assembly.
Fault effect and breakdown warning
Driver information
none
Service instruction
none