P0102
2D0F - P0102Information saved in
DME
Fault code
2D0F - P0102
Fault text
Air-mass sensor, signal
Fault description
Mass or Volume Air Flow 'A' Circuit Low
Condition for fault identification
Test condition:
Engine must be running
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
0.2 sec.
Action in service
1) Electrical check on sensor wire and electrical power
supply
2) Visual inspection of plug-in contacts (at component and
DME ends)
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON
Service instruction
none