Operation CHARM: Car repair manuals for everyone.

102B02

102B02 - P0102

Information saved in
DME

Fault code
102B02 - P0102

Fault text
Mass air flow sensor, correction signal: Short to earth

Fault description
The diagnostic function monitors whether the digital
temperature signal for Bank 1 switches between LOW and
HIGH.

Condition for fault identification
Test condition:
The fault is recognized when the digital temperature signal
is continuously at low level.
Potential problem source(s):
- Signal line: Short circuit to ground
Terminal condition: none
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Engine on

Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 3 sec.

Action in service
- Visual examination of plug-in contacts (at component and
DME ends) Perform electrical measurements on sensor wire,
power supply and ground (possible intermittent open!)
- Replace sensor

Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none

Driver information
Warning light:
- ECE emissions warning lamp: on
- US emissions warning lamp: on
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none

Service instruction
- none