Manufacturer Code Charts: 108102
108102 - P00ACInformation saved in
DME
Fault code
108102 - P00AC
Fault text
Intake-air temperature sensor 2, electric: short circuit to
ground
Fault description
The diagnostic function monitors the lower voltage limit on
the intake-air temperature sensor on Bank 2.
Condition for fault identification
Test condition:
The fault is recognized when the voltage of the intake-air
temperature sensor is < 0.10 V.
Potential problem source(s):
- Defect in wiring harness
- Intake air temperature sensor defective
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 1.5 sec.
Action in service
- Visual examination of plug-in contacts (at component and
DME ends) Perform electrical measurements on sensor wire,
power supply and ground (possible intermittent open!)
- Replace sensor
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none
Driver information
Warning light:
- ECE emissions warning lamp: on
- US emissions warning lamp: on
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- none