P0462
193002 - P0462Information saved in
DME
Fault code
193002 - P0462
Fault text
Fuel-level sensor, left, signal: short circuit to ground
Fault description
The fault is first stored in the junction box electronics and
then relayed to the DME.
Condition for fault identification
Test condition:
--
Potential problem source(s):
--
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- 21 sec. after Terminal 15 on
Other conditions:
- Engine on
Condition for fault memory entry
--
Action in service
The fault repair is implemented in 'Fuel gauge'.
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: off
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- With the JPE Terminal 15 is adequate to trigger entry of a
fault code, with the DME the engine must also be running.