P10D0
10C004 - P10D0Information saved in
DME
Fault code
10C004 - P10D0
Fault text
Charge-air temperature sensor, gradient: offset too high
Fault description
The diagnostic function monitors the signal from the charge-
air temperature sensor on Bank 1 for excessive offset.
Condition for fault identification
Test condition:
The fault is recognized when the charge-air temperature is
15 °C above the coolant temperature while the coolant
temperature is simultaneously roughly equal to the ambient
temperature.
Potential problem source(s):
- Defect in wiring harness
- Charge air temperature sensor defective
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 1.5 sec.
Action in service
- Visual inspection of the sensor and its wiring
- Measure sensor wire, power supply and ground
- Replace sensor
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- Slight reduction in power
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: on
- ECE electronic engine power reduction: on
- US electronic engine power reduction: on
- CC message: none
Service instruction
- none