Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Trouble Code Diagnosis

Condition Present:




Data Circuit:






CIRCUIT DESCRIPTION:

A damaged data line circuit or one of the components connected to the data line may cause multiple or intermittent setting of data line codes B333, B334, B335, B336, and/or B337. When operating normally, the serial data line voltage should continually fluctuate from 0.1 to 5.0 volts.

If the serial data line has been shorted to ground, the voltage at the ALDL will be 0 volts. If it has been shorted to voltage, it will be over 5.0 volts. If one of the components on the serial data line is affecting the data line voltage, the serial data voltage at the ALDL connector will be a steady value anywhere between 0.1 and 5.0 volts.