Troubleshooting Hints - Blower Controls
PROCEDURE 1.
Check the HTR A/C fuse by visual inspection.
2.
Check that ground G105 is clean and tight (V6 VIN N).
3.
Check that ground G112 is clean and tight (L4 VIN 4).
4.
Check that
blower motor connectors and the
blower motor relay are mated correctly and firmly seated.
5.
If blower runs all the time with the ignition switch in off, replace
blower relay.