Manifold Pressure/Vacuum Sensor: Service and Repair
MAP Sensor Service:
REMOVAL PROCEDURE 1.
Disconnect the MAP sensor electrical connector.
2.
Remove the MAP sensor attaching screws.
INSTALLATION PROCEDURE 1.
Install the MAP sensor attaching screw.
Tighten Screw to
2-4 Nm (18-35 lb in). 2.
Connect the MAP sensor electrical connector.