HVAC System - Manual
HVAC CONTROL MODULE REPLACEMENT
REMOVAL PROCEDURE
1. Remove the I/P cluster trim plate bezel.
2. Remove the HVAC control module retaining screws.
3. Pull the HVAC control module straight out from the I/P.
4. Disconnect the HVAC control module electrical connector.
INSTALLATION PROCEDURE
1. Connect the HVAC control module electrical connector.
IMPORTANT: The key should be in the off position when connecting the HVAC control module electrical connector to ensure proper calibration.
2. Install the HVAC control module into the I/P opening.
3. Install the HVAC control module retaining screws.
Tighten the screws to 2.5 N.m (22 lb in).
NOTE: Refer to Fastener Notice in Service Precautions.
4. Install the IP cluster trim plate bezel.
5. Start and allow the engine to run for a least one minute
IMPORTANT:
- Do not adjust any controls on the HVAC control module while the HVAC control module is self-calibrating. If interrupted, improper HVAC performance will result.
- The engine must be running for proper calibration to occur.