Operation CHARM: Car repair manuals for everyone.

Fuel System Diagnosis



Fuel System Diagnosis

System Description

The control module enables the fuel pump relay when the ignition switch is turned ON. The control module will disable the fuel pump relay within 2 seconds unless the control module detects ignition reference pulses. The control module continues to enable the fuel pump relay as long as ignition reference pulses are detected. The control module disables the fuel pump relay within 2 seconds if ignition reference pulses cease to be detected and the ignition remains ON.

The fuel system is a returnless on-demand design. The fuel pressure regulator is a part of the fuel sender assembly, eliminating the need for a return pipe from the engine. A returnless fuel system reduces the internal temperature of the fuel tank by not returning hot fuel from the engine to the fuel tank. Reducing the internal temperature of the fuel tank results in lower evaporative emissions.

The fuel tank stores the fuel supply. An electric turbine style fuel pump attaches to the fuel sender assembly inside the fuel tank. The fuel pump supplies high pressure fuel through the fuel filter, contained in the fuel sender assembly, and the fuel feed pipe to the fuel injection system. The fuel pump provides fuel at a higher rate of flow than is needed by the fuel injection system. The fuel pump also supplies fuel to a venturi pump located on the bottom of the fuel sender assembly. The function of the venturi pump is to fill the fuel sender assembly reservoir. The fuel pressure regulator, a part of the fuel sender assembly, maintains the correct fuel pressure to the fuel injection system. The fuel pump and sender assembly contains a reverse flow check valve. The check valve and the fuel pressure regulator maintain fuel pressure in the fuel feed pipe and the fuel rail in order to prevent long cracking times.

Test Description

Step 1 - Step 5:




Step 6 - Step 13:




The numbers below refer to the step numbers on the diagnostic table.
2. This step verifies that the fuel pump is operating.
4. This step tests for an internal fuel leak. If the fuel pressure drops during this test, then an internal loss of pressure is indicated.
7. This step isolates the condition. Replace the primary fuel tank module assembly, if the fuel pressure remains constant, after closing the valve on the fuel pipe shut-off adapter. Locate and replace the leaking fuel injector if the pressure continues to decrease after closing the valve on the adapter.
10. This step verifies that a circuit condition is not the cause of a fuel pressure concern. Inspect all fuel pump electrical circuits thoroughly.