Service Port HVAC: Service and Repair
Service Ports Replacement
REMOVAL PROCEDURE
TOOLS REQUIRED
J 39500-B A/C Refrigerant Recovery, Recycling and Recharging System
1. Recover the refrigerant from the system. Refer to Refrigerant Recovery and Recharging.
2. Remove the service fitting from the line.
INSTALLATION PROCEDURE
TOOLS REQUIRED
J 39400-A Electronic Halogen Leak Detector
1. Lobe O-ring with 525 refrigerant oil.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the service fitting to the line.
Tighten
Tighten service fitting to 12 N.m (9 lb ft).
3. Recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the A/C system. Refer to Leak Testing.