Accumulator HVAC: Service and Repair
ACCUMULATOR REPLACEMENTREMOVAL PROCEDURE
TOOLS REQUIRED
J 39500-B A/C Refrigerant Recovery, Recycling and Recharging System
1. Recover the refrigerant from the system. Refer to Refrigerant Recovery and Recharging. Service and Repair
2. Remove the suction hose retainer from the accumulator.
3. Remove the suction hose from the accumulator.
4. Remove the evaporator hose assembly from the accumulator.
5. Disconnect the accumulator retainer.
6. Remove the accumulator.
INSTALLATION PROCEDURE
TOOLS REQUIRED
J 39400-A Electronic Halogen Leak Detector
1. Install the accumulator.
2. Connect the accumulator retainer.
3. Install the evaporator hose assembly to the accumulator.
NOTE: Refer to Fastener Notice in Service Precautions.Vehicle Damage Warnings
4. Install the evaporator hose assembly retaining nut.
Tighten
Tighten the evaporator hose assembly to 20 N.m (15 lb ft).
5. Install the suction hose to the accumulator.
6. Install the suction hose retaining nut.
7. Tighten the retaining nut.
NOTE: Refer to Fastener Notice in Service Precautions.Vehicle Damage Warnings
Tighten
Tighten the suction hose retaining nut to 20 N.m (15 lb ft).
8. Recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging.Service and Repair
9. Leak test the A/C system. Refer to Leak Testing.Leak Testing - HVAC System - Automatic