Memory Seat Module (MSM) Definitions

Battery Voltage: The scan tool displays 0-16 volts. The level of battery voltage at the module.

Current: The scan tool displays 0.127.5 amps. The current measured during seat operation.

Belt Tower Down: The scan tool displays Inactive/Active. When the seat belt tower down switch is activated, the scan tool will momentarily display Active.

Belt Tower Up: The scan tool displays Inactive/Active. When the seat belt tower up switch is activated, the scan tool will momentarily display Active.

Belt Tower Sensor: The scan tool displays 0.5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the belt tower position. High scan tool values, volts or A/D, indicate that the belt tower is in the up position and low values indicate that the belt tower is in the down position.