Canister Purge Control Valve: Service and Repair
EVAP Purge Valve:
REMOVAL PROCEDURE
1. Turn OFF the ignition.
2. Note the position of the [1][2]EVAP hoses for installation.
3. Disconnect the electrical connector and hoses from the EVAP canister purge valve.
4. Remove the bolt from the valve mounting bracket.
5. Remove the [1][2]EVAP purge valve.
INSTALLATION PROCEDURE
1. Position the EVAP canister purge valve on the manifold.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the bolt and secure the EVAP canister purge valve.
Tighten
Tighten the purge valve retaining bolt to 10 N.m (88 lb in).
3. Connect the electrical connector and hoses to the valve.