Generalized Testing




Generalized Testing





If the source of the leak is not obvious, use a water test stand and perform generalized leak test method. Once the general leak area is located, use a water hose or an air hose and perform one of the localized test procedures to pinpoint the specific leak area. Refer to Water Hose Test (Water Hose Test) or Air Hose Test (Air Hose Test).

1. Subject the vehicle to a water spray of 155 KPa (22 psi) for 10 to 20 minutes.
2. When testing the windshield, set the stands 60 cm (24 in) from the corner of the windshield with the nozzles pointing approximately 30 degrees down and 30 degrees toward the rear of the vehicle.
3. When testing the side of the vehicle, set the stands so the nozzles point approximately 30 degrees down and 45 degrees toward the rear of the vehicle.
4. When testing the rear window and rear compartment lid, set the stands 60 cm (24 in) from the corner of the rear window with the nozzles pointing approximately 30 degrees down and 30 degrees toward the front of the vehicle.