Charge Indicator Inoperative
Charge Indicator Inoperative
Electrical Information Reference
* Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle.
* Circuit Testing Circuit Testing.
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections.
The alternator warning indicator is only illuminated for 6 seconds after the ignition is switched to the ON position with the engine OFF.
Warning:
Refer to Safety Glasses Warning Safety Glasses Warning.
1. Carry out the Diagnostic System Check.
2. Ignition on alternator warning light should illuminate for 6 second.
• If the alternator warning does not illuminate, connect the scan tool and command the alternator warning light ON.
• If the light does not illuminate replace instrument panel cluster.
Repair Instructions
Instrument Cluster Replacement Service and Repair.