DTC Descriptors

DTC P0030
- HO2S Heater Control Circuit Bank 1 Sensor 1

DTC P0036
- HO2S Heater Control Circuit Bank 1 Sensor 2

DTC P0053
- HO2S Heater Resistance Circuit Bank 1 Sensor 1

DTC P0054
- HO2S Heater Resistance Circuit Bank 1 Sensor 2

DTC P0135
- HO2S Heater Performance Bank 1 Sensor 1

DTC P0141
- HO2S Heater Performance Bank 1 Sensor 2

Diagnostic Fault Information






Typical Scan Tool Data






Circuit/System Description

Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content in the exhaust stream. The HO2S must reach operating temperature to provide an accurate voltage signal. A heating element inside the HO2S minimizes the time required for the sensors to reach operating temperature. Voltage is provided to the heater by an ignition voltage circuit through a fuse. With the engine running, ground is provided to the heater by the HO2S heater low control circuit through a low side driver within the engine control module (ECM). The ECM uses pulse width modulation (PWM) to control the HO2S heater operation to maintain a specific HO2S operating temperature range.

Conditions for Running the DTC

P0030 or P0036
* The Ignition 1 Signal parameter is between 11-18 volts.
* The engine speed is more than 400 RPM.
* DTC P0030 or P0036 runs continuously when the above conditions are met for 1 second.

P0053 or P0054
* DTCs P0112, P0113, P0117, P0118 are not set.
* The engine is started.
* The ignition voltage is less than 18 volts.
* The ignition is OFF for more than 10 hours.
* The Engine Coolant Temperature (ECT) Sensor parameter is between -30 to +45°C (-22 to +113°F) at engine start-up.
* The Engine Coolant Temperature (ECT) Sensor parameter minus the Intake Air Temperature (IAT) Sensor parameter is less than 8°C (46°F) at engine start-up.
* DTC P0053 or P0054 run once per drive cycle when the above conditions are met.

P0135
* DTCs P0068, P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0125, P0128, P0201, P0202, P0203, P0204, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set.
* The ECT Sensor parameter is more than 50°C (122°F).
* The Ignition 1 Signal parameter is between 10-18 volts.
* The MAF Sensor parameter is between 3-40 g/s.
* The Engine Run Time parameter is more than 300 seconds.
* The Engine Speed parameter is between 500-3,000 RPM.
* DTC P0135 runs the heater current test once per drive cycle when the above conditions are met for 120 seconds.

P0141
* DTCs P0068, P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0120, P0121, P0122, P0123, P0125, P0128, P0201, P0202, P0203, P0204, P0220, P0222, P0223, P0442, P0443, P0446, P0449, P0455, P0496, P1516, P2101, P2119, P2135, P2176 are not set.
* The ECT Sensor parameter is more than 50°C (122°F).
* The Ignition 1 Signal parameter is between 10-18 volts.
* The MAF Sensor parameter is between 3-40 g/s.
* The Engine Run Time parameter is more than 300 seconds.
* The Engine Speed parameter is between 500-3,000 RPM.
* DTC P0141 runs the heater current test twice per drive cycle when the above conditions are met for 120 seconds.

Conditions for Setting the DTC

P0030 or P0036
* The ECM detects that the affected HO2S heater low control circuit is not within a specified range.
* DTCs P0030 or P0036 set within 3 seconds when the above condition is met.

P0053
* The ECM detects that the affected HO2S heater low control circuit parameter is between 2.185-9.512 ohms at engine start-up.
* DTCs P0053 sets within 1 second when the above condition is met.

P0054
* The control module detects that the affected HO2S heater low control circuit parameter is between 4.119-10.810 ohms at engine start-up.
* DTC P0054 sets within 1 second when the above condition is met.

P0135
* The ECM detects that the HO2S 1 heater current parameter is more than 3.125 amps or less than 0.25 amp.
* DTC P0135 sets within 120 seconds during the heater current test when the above condition is met.

P0141
* The ECM detects that the HO2S 2 heater current parameter is more than 2.875 amps or less than 0.25 amp.
* DTC P0141 sets within 120 seconds during the heater current test when the above condition is met.

Action Taken When the DTC Sets

DTC P0030, P0036, P0053, P0054, P0135, or P0141 are type B DTCs.

Conditions for Clearing the MIL/DTC

DTC P0030, P0036, P0053, P0054, P0135, or P0141 are type B DTCs.

Circuit/System Verification

1. Allow the engine to reach operating temperature. With the engine running, observe the HO2S Heater parameter with a scan tool. The value should vary from below 2A to above 1A.
2. With the engine running at operating temperature, observe the HO2S Heater parameter with a scan tool and manipulate the related wiring and connectors.

^ If manipulation does affect the parameter then repair the harness or connector.

3. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.

Circuit/System Testing

Important: You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.

1. Ignition OFF, disconnect the harness connector at the appropriate HO2S.
2. Ignition ON, verify that a test lamp illuminates between the appropriate HO2S heater voltage supply circuit terminal D and ground.

^ If the test lamp does not illuminate, test the HO2S heater voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal and the HO2S heater voltage supply circuit fuse is open, test all components connected to the fuse and replace as necessary.

3. Ignition ON, verify that a test lamp does not illuminate between the appropriate HO2S heater voltage supply circuit terminal D and the appropriate HO2S heater low control circuit terminal listed below:

* B1S1 terminal E
* B1S2 terminal C
* B2S1 terminal E
* B2S2 terminal C

^ If the lamp illuminates, test the HO2S heater low control circuit for a short to ground. If the circuit tests normal, replace the ECM.

4. Engine running, leave the test lamp connected from the previous step. The lamp should flash or be ON steady.

^ If the test lamp is not ON steady or flashing, test the HO2S heater low control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.

Important:
* The output driver should detect a short to voltage and turn OFF. If a resistance fault is present the driver will remain ON and the scan tool will display more than 0.0 amp. Less than 10 ohms may set a DTC.

* Performing this test may set additional DTCs.

Ignition OFF, install a 30A fused jumper wire between the appropriate HO2S heater voltage supply circuit terminal D and the appropriate HO2S heater low control circuit terminal listed below:

* B1S1 terminal E
* B1S2 terminal C
* B2S1 terminal E
* B2S2 terminal C

5. Engine running, verify the appropriate scan tool HO2S Heater parameter is less than 0.1 amp.

^ If more than the specified range, test the HO2S heater voltage supply and HO2S heater low control circuits for more than 1 ohm. If the circuits test normal, replace the ECM.

6. If the ECM and all circuits test normal, replace the appropriate HO2S.

Repair Instructions

Notice: Refer to Heated Oxygen Sensor Resistance Learn Reset Notice.

Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests

* Heated Oxygen Sensor Replacement - Bank 1 Sensor 1
* Heated Oxygen Sensor Replacement - Bank 1 Sensor 2