Operation CHARM: Car repair manuals for everyone.

P0523



DTC P0523

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P0523
- Engine Oil Pressure (EOP) Sensor Circuit High Voltage

Diagnostic Fault Information






Circuit Description

The engine oil pressure (EOP) sensor changes resistance based on engine oil pressure. The engine control module (ECM) monitors the signal circuit of the EOP sensor. When the oil pressure is high, the sensor resistance is high, and the ECM senses a high signal voltage. When the oil pressure is low, the sensor resistance is low, and the ECM senses a low signal voltage. The ECM sends the engine oil pressure information to the instrument panel cluster (IPC) via the class 2 serial data circuit.

Conditions for Running the DTC

* The engine is running.
* DTC P1635 is not present.

Conditions for Setting the DTC

* The ECM detects that the EOP sensor signal circuit is greater than 4.6 volts.
* The above condition is present for greater than 9 seconds.

Action Taken When the DTC Sets

The ECM records the operating conditions at the time that the diagnostic test fails. The ECM displays this information in the Failure Records on the scan tool.

Conditions for Clearing the DTC

* The DTC becomes history when the conditions for setting the DTC are no longer present.
* The history DTC is cleared after 40 malfunction-free warm-up cycles.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the EOP sensor.
2. Ignition OFF, test for less than 1 ohm of resistance between the low reference circuit terminal 1 and ground.

^ If greater than specified, test the low reference circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.

3. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 2 and ground.

^ If less than 4.8 volts, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
^ If greater than 5.2 volts, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.

4. Install a 3-amp fused jumper wire between the signal circuit terminal 3 and the low reference circuit terminal 1. Verify the scan tool Engine Oil Pressure Sensor parameter is less than 0.4 volt.

^ If greater than specified, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.

5. If all circuits test normal, test or replace the EOP sensor.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests

* Engine Oil Pressure Sensor and/or Switch Replacement