Operation CHARM: Car repair manuals for everyone.

Garage Door Opener Inoperative



Garage Door Opener Inoperative

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Circuit/System Description

The garage door opener (GDO) is a transmitter operating between 288 and 399 MHz. The GDO has 3 buttons that may be programmed for individual transmitter/receiver combinations to control up to 3 GDOs, security gates, and lighting systems. Each button represents a transmitter code section of the transmitter, which operates separately from any other button, and may be considered a separate transmitter.

Diagnostic Aids

GDO operation is dependent on the position of the valet switch, if equipped. If the vehicle is equipped with a valet switch, verify it is not in valet mode before continuing with the diagnostics.

Special Tools

J 41540 Universal Home Remote Tester

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the GDO.
2. Ignition OFF, test for less than 1 ohm of resistance between the ground circuit terminal 3 and ground.

^ If greater than the specified range, test the ground circuit for an open/high resistance.

3. Ignition ON, verify a test lamp illuminates between the B+ circuit terminal 1 and ground.

^ If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

4. Hold the 2 outer buttons on the GDO until the LED stops flashing. Place the J 41540 adjacent to the GDO and individually press each button of the GDO. The tester should indicate when each button is pressed.

^ If one or more of the buttons does not respond when each button is pressed, replace the GDO.

5. Program the GDO with the customer's device. The GDO should learn the device.

^ If the device is not learned, a possible rolling code or incompatibility with the GDO receiver will prevent programming. Contact 1-800-355-3515.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests