Blower Motor Resistor: Testing and Inspection
RESISTOR RESISTANCE CHECKUse an ohmmeter to measure the resistance between the terminals as indicated below. Check that the measured value is at the standard value.
Standard value: Measurement terminal = Standard value (Ohms)
Between terminals 3 - 2 (LO) =
1.83 Between terminals 3 - 4 (ML) =
0.87 Between terminals 3 - 1 (MH) =
0.31